Derek Booth Consultancy t/a DBCON Corner of Spa Road and Rotokawa Street PO Box 1123 TAUPO 3351 Ph.: 0800 232266 www.dbcon.co.nz Date: 31 January 2014 Our Job Ref: 140605 CAMBRIDGE PARK SUBDIVISION Lot 202 3886 – 3910 CAMBRIDGE ROAD CAMBRIDGE REPORT ON SUBDIVISION EARTHWORKS AND RECOMMENDATIONS FOR BUILDING DEVELOPEMENT Lots 1 – 10 Prepared by: James Dunning ____________________________ Engineering Technician Peer Reviewed by: Michael Richardson ____________________________ Chartered Professional Engineer CPENG – 1005467 1.0 Background The Cambridge Park Subdivision is the development of cultivated and/or pastoral land for residential development. The subdivision is accessed off Cambridge Road via an existing round a bout. The fully developed subdivision will consist of 210 residential lots. This report covers Lot 202, consisting of 10 residential lots. The land form upon which Lot 202 is located was generally fairly flat and so only minor earthworks were undertaken during the construction of the subdivision. 2.0 Geological Description of the Land Geologically, the landform on which the Cambridge Park residential development is located is an old river terrace. The soils underlying the subdivision consist of the Hinuera Formation, ie alluvial sediments (pumiceous sand, silt and gravel) which were deposited by the Waikato River over thousands of years. 3.0 Subdivision Earthworks In general terms, earthworks undertaken during the construction of the subdivision consisted of minor cuts and fills to form a near level site for the lots. In detail, the earthworks undertaken as part of construction of the subdivision development consisted of the following: Placement of controlled fill to a maximum depth of 1.4m but generally 0.2m to 0.8m on all or parts of lots 1 to 10 (as shown in Appendix B) to infill shallow depressions to create level lots. Cuts to a maximum depth of 0.5m on all or parts of lots 2 to 10 (as shown in Appendix B) to create level lots. The excavated material was used as the controlled fill in the low lying areas noted above. Excavations to form the road network and the trenches in which the, power, water, gas and sewerage services are located. All controlled filling undertaken by the developer was completed in accordance with NZS 4431:1989 "Earth Fill for Residential Development". All vegetation, topsoil and near surface organic soils were removed from the areas to be filled prior to the controlled fill being placed. 4.0 Ground Conditions Ground conditions across the Cambridge Park Subdivision were investigated during May 2014 by hand augered drill holes with accompanying Scala Penetrometer tests to a depth of approximately 2.0m below ground level on each of the 10 lots. Logs of the materials encountered in the drill holes and the soil strengths are attached in Appendix A. Based on the auger hole results and our experience with similar sub soils in the area, subsurface conditions on the lots in Lot 202 of Cambridge Park generally consist of 0.1m to 0.3m of dark brown silt (topsoil) overlying alternating layers of silt, sandy silt and gravelly sands to a depth of at least 2.0m below ground level. The soil densities are generally slightly loose near the surface and increasing with depth. As a general rule, the near surface silt layers were looser than the underlying gravelly sand layers as inferred from the Scala Penetrometer soil test data. The soils strength tests on the lots indicate that the soils generally have sufficient density to provide the required 300 kPa ultimate foundation bearing capacity for standard residential development in accordance with NZS 3604:2011, but the depth to 300kPa (ultimate bearing capacity) ground varied from a depth of 0.2m to 0.9m. Static groundwater level (the ground water table) was not encountered to a depth of at least 2m below ground level at the date of testing (May 2014). 5.0 Building Development Recommendations Based on the results to date and subject to the recommendations in this report, the lots in Cambridge Park Lot 202 Subdivision are considered suitable for residential development in accordance with NZS 3604:2011 "Timber Framed Buildings': However, due to the near surface soils being loose in some areas, excavations to remove the loose soils followed by the placement of controlled fill will be required where the near surface soils are not able to provide an ultimate foundation bearing pressure of 300 kPa. To provide guidance on the soil strengths and foundation systems recommended for each lot in Cambridge Park Lot 202, the following table has been prepared. The foundation recommendations detailed in the attached table are based on the assumption that the foundations for the proposed dwellings on each lot will be formed at a minimum depth of 0.3m below current ground level. If basement type foundations are proposed (which is very unlikely on this subdivision due to the near level topography), then additional soil tests will need to be carried out to confirm that the required 300 kPa ultimate bearing pressure is available at the underside of the basement foundations. 5.1 Cambridge Park Lot 202 Foundation Recommendations The augered holes and Scala Penetrometer tests undertaken to date indicate that the soils on lots 1 to 10 from a depth of approximately 0.9m below ground level are generally adequate for 300 kPa ultimate bearing. It is all possible that on some lots excavations to depths greater the values tabulated below may be required under the load bearing footing lines to remove isolated soft pockets of soil. The foundation system recommended for each lot is based on one soil test completed near the centre of each lot. Whilst we believe these tests to provide a good representation of the soils found on the lots, it may necessitate further soil testing being required prior to commencing the foundation works for a proposed dwelling. In addition, excavations to form the foundation sand pads that are undertaken in wet weather may result in excavation depths exceeding the depths noted below if the silty and sandy subgrade soils are softened by rainwater ponding on the sites. Foundation Recommendations for Lot 202 Of Cambridge Park Subdivision Depth to 300 kPa Lot No. Ultimate bearing capacity 1 0.3m 2 0.3m 3 0.3m 4 0.9m 5 0.3m 6 0.3m 7 0.3m 8 0.5m 9 0.7m 10 0.3m Recommended Foundation System NZS3604 foundations NZS3604 foundations NZS3604 foundations NZS3604 foundations on compacted sand pad NZS3604 foundations NZS3604 foundations NZS3604 foundations NZS3604 foundations on compacted sand pad NZS3604 foundations on compacted sand pad NZS3604 foundations Minimum Foundation Excavation Depth Below Finished Ground Level 0.3m 0.3m 0.3m 0.6m 0.3m 0.3m 0.3m 0.5m 0.6m 0.3m Notes: 1. The foundation recommendations above have been specified assuming all topsoil and organic 2. 3. material is removed. And these foundations are based on no further modification of the soils below the topsoil depth as specified in right hand column. Any foundation designs other than that specified above will be required to have a Chartered Engineer confirm the design. Any compacted backfilling of lots to achieve the desired finish floor level shall be compacted to a minimum 300kPa Ultimate bearing pressure. 5.2 Cambridge Park Stage Lot 202 Storm water Recommendations The hand augered percolation tests located approximately at the centre of each lot, confirm that the gravelly sand sub soils are relatively free draining soils. Only lots 2 to 8 were able to be drilled to a depth suitable to carry out a percolation test. The percolation tests completed at the test locations indicate that the soils are suitable for the on-site disposal of storm water and percolation rates of between 310 mm/hr to 420 mm/hr were achieved. Preliminary recommendations for soak holes on the property were determined based on the following design parameters: Depth to the ground water table exceeds 3m Design soakage rate =310 mm/hr For the house sites, the design storm event is a 10 year return period, 1 hour duration The assumed impermeable area on each lot (house, driveway etc.) has been assumed to be 300 m2 Using the above parameters, we have calculated the following will be required: For the lots, we would recommend a one 14m long x 1m wide x 2m deep soak trench (soakage trench shape can be altered providing overall volume is obtained)will be require to process the design 10 year storm. Due to not being able to conduct a percolation test on every lot we would recommend a percolation tests and design be carried out for each lot prior to construction on site. For storm events exceeding the design 10 year period noted above, a designated overland flow path will need to be provided to ensure that storm water can be safely discharged to the street. 6.0 Conclusion Based on the investigations undertaken to date and subject to the development recommendations contained in this report, the land designated as the Cambridge Park Subdivision (Lot 202) is considered suitable for residential development in accordance with NZS 3604:2011. The following recommendations are given to guide building construction on the lots, but additional detailed soils investigations on each lot are recommended prior to designing the appropriate foundation system. 6.1 6.2 For lots 1 to 10 an ultimate foundation bearing pressure of 300 kPa is available at a depth of between 0.3m and 0.7m below ground level. A standard concrete slab (NZS3604) foundations supported on a sand pad can be used to support the proposed houses on these lots. Specific hand auger and Scala Penetrometer tests are recommended on all lots prior to development to confirm the foundation recommendations provided above are appropriate. A Statement of Professional Opinion as to the Suitability of Land for Building Construction (i.e. the NZS 4404:2004 Schedule 2A Certificate for the Cambridge Park Lot 202 Subdivision) is attached. 7.0 Limitations The recommendations and options contained in this report are based on data from the field investigations described above. Inferences about the nature and continuity of ground conditions away from test locations are considered reasonable, but cannot be guaranteed. During development of the lots, a person competent to assess should examine ground conditions exposed in foundation excavations and cuttings to confirm whether the conditions are compatible with the assumptions made in this report. In all circumstances, if ground conditions differ from those described in this report the matter should be referred to a geotechnical engineer. This professional opinion does not remove the requirement for the normal inspection and verification of foundation conditions for all buildings constructed on the lots. This report has been prepared for the particular project described in the owner's brief to us. No responsibility is accepted for the use of any part of this report in other contexts or for any other purposes. NZS 4404: 2010 SCHEDULE2A STATEMENT OF PROFESSIONAL OPINION AS TO SUITABILITY OF LAND FOR BUILDING CONSTRUCTION Development Cambridge Park Subdivision Lot 202 Developer Cambridge Park Ltd Location 3886 – 3910 Cambridge, Cambridge I, Michael Richardson (Full Name) of DBCON, PO Box 1123, Taupo Hereby confirm that: 1.0 2.0 3.0 I am a geo-professional as defined in clause 1.2.2 of NZS 4404:2010 and was retained by the developer as the geoprofessional on the above development. The extent of my inspections during construction, and the results of all tests carried out are described in my geotechnical completion report dated 11 June 2014. In my professional opinion, not to be construed as a guarantee, I consider that (delete as appropriate): a. The earth fills shown on the attached Cambridge Environmental Plan No. 3707-2-02 have been placed in compliance with the requirements of the Waipa District Council and my specification. b. The completed works give due regard to land slope and foundation stability considerations. c. The original ground not affected by filling is suitable for the erection thereon of buildings designed according to NZS 3604 provided that: i. Those lots where the ultimate bearing pressure is less than 300 kPa can have the proposed houses supported on either a stiffened floor slab (if a minimum of 225 kPa is available) or a Raft Style floor slab (if a minimum of 150 kPa is available) ii. For the balance of the lots an ultimate foundation bearing pressure of 300 kPa is available at a depth of 0.3m below ground level. A standard concrete slab foundation supported on a sand pad can be used to support the proposed houses on these lots. iii. Specific hand auger and Scala Penetrometer tests are recommended on all lots prior to development to confirm the foundation recommendations provided above are appropriate d. The filled ground is suitable for the erection thereon of buildings designed according to NZS 3604 provided that: i. Those lots where the ultimate bearing pressure is less than 300 kPa can have the proposed houses supported on either a stiffened floor slab (if a minimum of 225 kPa is available) or a Raft style floor slab (if a minimum of 150 kPa is available) ii. For the balance of the lots an ultimate foundation bearing pressure of 300 kPa is available at a depth of 0.3m below ground level. A standard concrete slab foundation supported on a sand pad can be used to support the proposed houses on these lots iii. Specific hand auger and Scala Penetrometer tests are recommended on all lots prior to development to confirm the foundation recommendations provided above are appropriate e. The original ground not affected by filling and the filled ground are not subject to erosion, subsidence or slippage in accordance with the provisions of section 106 of the Resource Management Act 1991 provided that: i. Those lots where the ultimate bearing pressure is less than 300 kPa can have the proposed houses supported on either a stiffened floor slab (if a minimum of 225 kPa is available) or a Raft style floor slab (if a minimum of 150 kPa is available). ii. For the balance of the lots an ultimate foundation bearing pressure of 300 kPa is available at a depth of 0.3m below ground level. A standard concrete slab foundation supported on a sand pad can be used to support the proposed houses on these lots iii. Specific hand auger and Scala Penetrometer tests are recommended on all lots prior to development to confirm the foundation recommendations provided above are appropriate NOTE: The sub-clauses in clause 3 may be deleted or added to as appropriate. 4.0 5.0 This professional opinion is furnished to the TA and the developer for their purposes alone on the express condition that it will not be relied upon by any other person and does not remove the necessity for the normal inspection of foundation conditions at the time of erection of any dwelling. This certificate shall be read in conjunction with my geotechnical report referred to in clause 2 above and shall not be copied or reproduced except in conjunction with the full geotechnical completion report. Signed…………………………………………………………….. Michael Richardson Chartered Professional Engineer CPEng 1005467 …………………………………………………………………….. (Name, title and professional qualifications) Date……………………………………………11 June 2014 APPENDIX A TEST RESULTS Project Job ref Cambridge Park Subivision Drawing ref calculations by P.O Box 1123, Taupo Phone: 07 3785067 Scala (blows/100mm) revision sheet no jmd 1 Element Date Fax: 07 3782800 www.dbcon.co.nz Depth 140605 Lot 1 May-14 Soil Description Percolation Test 100 0 200 4 300 4 10 50 400 500 20 EOB SANDY LOAM, light brown, some gravel, damp 15 20 UNABLE TO EXTRACT, gravel 30 TOPSOIL, some fine gravel 600 Time (min) Drop (mm) 5 650 25 700 800 35 900 1000 40 45 1100 50 1200 55 1300 60 1400 1500 Soakage rate (mm/hr) = 1600 0 1700 Average (last 6 results) 1800 1900 2000 0.00 2100 2200 2300 2400 2500 2600 2700 2800 2900 3000 3100 3200 3300 3400 3500 Notes: 1 Weather was overcast but warm 2 No Ground water was detected 3 4 5 mm/5mins Project Job ref 140605 Cambridge Park Subivision Drawing ref calculations by P.O Box 1123, Taupo Phone: 07 3785067 Fax: 07 3782800 www.dbcon.co.nz Scala Depth (blows/100mm) revision sheet no jmd 2 Element Date Lot 2 Soil Description May-14 Sample / Temperature 100 0 Time (min) 200 4 5 505 300 6 10 145 400 11 15 80 500 13 20 65 600 25 55 700 30 50 800 35 40 900 40 35 1000 45 30 TOPSOIL, some fine gravel SAND, coarse, light grey, some fine gravel, damp 1100 Drop (mm) 50 30 1200 55 25 1300 60 20 Soakage rate (mm/hr) = 360 1400 1500 1600 UNABLE TO EXTRACT, gravel 1700 Average (last 6 results) 1800 1900 30.00 2000 2100 2200 2300 2400 2500 2600 2700 2800 2900 3000 3100 3200 3300 3400 3500 Notes: 1 Weather was overcast but warm 2 No Ground water was detected 3 4 5 mm/5mins Project Job ref Cambridge Park Subivision Drawing ref calculations by P.O Box 1123, Taupo Phone: 07 3785067 Fax: 07 3782800 www.dbcon.co.nz Scala Depth (blows/100mm) 100 0 200 3 300 20 140605 revision sheet no jmd 3 Element Date May-14 Lot 3 Soil Description TOPSOIL Sample / Temperature Time (min) Drop (mm) 5 710 10 140 400 15 90 500 20 70 600 25 40 700 30 35 800 35 30 40 30 1000 45 25 1100 50 25 1200 55 25 1300 60 20 Soakage rate (mm/hr) = 310 SAND, coarse, mottled light brown/light grey, some fine gravel, damp 900 1400 1500 UNABLE TO EXTRACT, gravel 1600 1700 Average (last 6 results) 1800 1900 25.83 2000 2100 2200 2300 2400 2500 2600 2700 2800 2900 3000 3100 3200 3300 3400 3500 Notes: 1 Weather was overcast but warm 2 No Ground water was detected 3 4 5 mm/5mins Project Job ref Cambridge Park Subivision Drawing ref calculations by P.O Box 1123, Taupo Phone: 07 3785067 Fax: 07 3782800 www.dbcon.co.nz Scala Depth (blows/100mm) 140605 revision sheet no jmd 4 Element Date May-14 Lot 4 Soil Description Sample / Temperature 100 0 Time (min) Drop (mm) 200 4 5 410 300 6 10 95 400 4 15 80 500 5 20 60 600 3 25 55 700 3 30 50 TOPSOIL, some fine gravel SILTY LOAM, light brown, some fine gravel 800 3 35 50 900 20 40 40 1000 45 35 1100 50 30 1200 55 30 60 25 Soakage rate (mm/hr) = 420 SAND, coarse, mottled light brown/light grey, some fine gravel, damp 1300 1400 1500 1600 1700 UNABLE TO EXTRACT, gravel 1800 1900 Average (last 6 results) 35.00 2000 2100 2200 2300 2400 2500 2600 2700 2800 2900 3000 3100 3200 3300 3400 3500 Notes: 1 Weather was overcast but warm 2 No Ground water was detected 3 4 5 mm/5mins Project Job ref 140605 Cambridge Park Subivision Drawing ref calculations by P.O Box 1123, Taupo Phone: 07 3785067 Fax: 07 3782800 www.dbcon.co.nz Scala Depth (blows/100mm) 100 0 200 4 300 6 400 5 500 4 600 20 revision sheet no jmd 5 Element Date May-14 Lot 5 Soil Description Sample / Temperature Time (min) TOPSOIL, some fine gravel Drop (mm) 5 290 10 125 SILTY LOAM, light brown 15 95 SILTY LOAM, light brown, some fine gravel 20 50 25 50 700 30 40 800 35 30 900 40 30 1000 45 30 SAND, light brown, some gravel, damp 1100 50 25 1200 55 25 1300 60 20 Soakage rate (mm/hr) = 320 1400 1500 UNABLE TO EXTRACT, gravel 1600 1700 Average (last 6 results) 1800 1900 26.67 2000 2100 2200 2300 2400 2500 2600 2700 2800 2900 3000 3100 3200 3300 3400 3500 Notes: 1 0 2 No Ground water was detected 3 4 5 mm/5mins Project Job ref Cambridge Park Subivision Drawing ref calculations by P.O Box 1123, Taupo Phone: 07 3785067 Fax: 07 3782800 www.dbcon.co.nz Scala Depth (blows/100mm) 100 0 200 4 300 4 400 20 140605 revision sheet no jmd 6 Element Date Lot 6 Soil Description May-14 Sample / Temperature Time (min) TOPSOIL, some fine gravel SANDY LOAM, light brown, some fine gravel Drop (mm) 5 460 10 110 15 90 500 20 85 600 25 70 700 30 50 800 35 40 900 40 35 45 30 1100 50 30 1200 55 25 1300 60 25 Soakage rate (mm/hr) = 370 SAND, light brown, some gravel, damp 1000 1400 UNABLE TO EXTRACT, gravel 1500 1600 1700 Average (last 6 results) 1800 1900 30.83 2000 2100 2200 2300 2400 2500 2600 2700 2800 2900 3000 3100 3200 3300 3400 3500 Notes: 1 0 2 No Ground water was detected 3 4 5 mm/5mins Project Job ref Cambridge Park Subivision Drawing ref calculations by P.O Box 1123, Taupo Phone: 07 3785067 Fax: 07 3782800 www.dbcon.co.nz Scala Depth (blows/100mm) 100 0 200 5 300 8 400 20 140605 revision sheet no jmd 7 Element Date May-14 Lot 7 Soil Description Sample / Temperature Time (min) TOPSOIL, some fine gravel SANDY LOAM, light brown, some fine gravel Drop (mm) 5 500 10 120 15 75 500 20 60 600 25 50 700 30 40 800 35 40 900 40 35 45 30 1100 50 30 1200 55 25 1300 60 20 Soakage rate (mm/hr) = 360 SAND, light brown, some gravel, damp 1000 1400 1500 UNABLE TO EXTRACT, gravel 1600 1700 Average (last 6 results) 1800 1900 30.00 2000 2100 2200 2300 2400 2500 2600 2700 2800 2900 3000 3100 3200 3300 3400 3500 Notes: 1 0 2 No Ground water was detected 3 4 5 mm/5mins Project Job ref Cambridge Park Subdivision Drawing ref calculations by P.O Box 1123, Taupo Phone: 07 3785067 Scala (blows/100mm) revision sheet no jmd 8 Element Date Fax: 07 3782800 www.dbcon.co.nz Depth 140605 Lot 8 May-14 Soil Description Percolation Test 100 0 Time (min) 200 3 5 535 300 4 10 225 400 500 3 5 15 20 150 75 TOPSOIL, some fine gravel Drop (mm) 600 7 25 50 700 14 30 40 800 20 35 40 40 45 35 30 1100 50 25 1200 55 20 60 20 Soakage rate (mm/hr) = 340 900 1000 SAND, coarse, light grey, some gravel, damp UNABLE TO EXTRACT, gravel 1300 1400 1500 1600 1700 Average (last 6 results) 1800 1900 2000 28.33 2100 2200 2300 2400 2500 2600 2700 2800 2900 3000 3100 3200 3300 3400 3500 Notes: 1 Weather was overcast but warm 2 No Ground water was detected 3 4 5 mm/5mins Project Job ref 140605 Cambridge Park Subdivision Drawing ref calculations by P.O Box 1123, Taupo Phone: 07 3785067 Fax: 07 3782800 www.dbcon.co.nz Scala Depth (blows/100mm) revision sheet no jmd 9 Element Date Lot 9 Soil Description May-14 Sample / Temperature 100 0 TOPSOIL Time (min) 200 4 SILTY LOAM, light brown 5 755 300 2 10 115 400 1 15 40 500 2 20 40 600 1 25 35 700 8 800 20 SILTY LOAM, light brown, some fine gravel SAND, coarse, light grey, some fine gravel, damp 900 Drop (mm) 30 35 40 1000 UNABLE TO EXTRACT, gravel 45 1100 50 1200 55 1300 60 1400 1500 Soakage rate (mm/hr) = 1600 0 1700 Average (last 6 results) 1800 1900 0.00 2000 2100 2200 2300 2400 2500 2600 2700 2800 2900 3000 3100 3200 3300 3400 3500 Notes: 1 Weather was overcast but warm 2 No Ground water was detected 3 4 5 mm/5mins Project Job ref Cambridge Park Subdivision Drawing ref calculations by P.O Box 1123, Taupo Phone: 07 3785067 Fax: 07 3782800 www.dbcon.co.nz Scala Depth (blows/100mm) 100 0 200 5 300 6 400 8 500 20 600 sheet no 10 Element Date May-14 Lot 10 Soil Description TOPSOIL SANDY LOAM, mottled light brown/light grey, some fine gravel Sample / Temperature Time (min) Drop (mm) 5 605 10 105 15 80 20 UNABLE TO EXTRACT, gravel 800 revision jmd SILTY LOAM, light brown, some fine gravel 700 140605 25 30 35 900 40 1000 45 1100 50 1200 55 1300 60 1400 1500 Soakage rate (mm/hr) = 1600 0 1700 Average (last 6 results) 1800 1900 0.00 2000 2100 2200 2300 2400 2500 2600 2700 2800 2900 3000 3100 3200 3300 3400 3500 Notes: 1 Weather was overcast but warm 2 No Ground water was detected 3 4 5 mm/5mins Soil Investigation Results 25 20 Test Location 1 Test Location 2 Blows per 100mm 15 Test Location 3 Test Location 4 Test Location 5 Test Location 6 10 Test Location 7 300 kPa 150 kPa 5 0 100 300 500 700 900 1100 1300 1500 1700 1900 Depth (mm) 2100 2300 2500 2700 2900 Soil Investigation Results 25 20 Test Location 8 Blows per 100mm 15 Test Location 9 Test Location 10 10 300 kPa 150 kPa 5 0 100 300 500 700 900 1100 1300 1500 1700 1900 Depth (mm) 2100 2300 2500 2700 2900 APPENDIX B PLANS
© Copyright 2026 Paperzz