stair layouts guide - JELD-WEN

Stair Layouts
guide
Stair Layouts
JELD-WEN manufactures all staircases to order in almost any
design, size or specification. However, to help plan your flight, our
20 most popular layouts are listed on the following pages together
with the critical dimensions relevant to each design including the
trimming dimension necessary to obtain headroom clearance.
Our specialist stairs team is always on hand to offer help and
advice on any aspect of design, construction or Part ‘K’ of the
Building Regulations. You can contact them on 01664 484613
or speak to your dedicated stairs technician.
Layout A
Dimension 'B' : Face of bottom riser to back of top riser
2757
Dimension ‘B’: 2757
3
2
4
Loose
229
229
188 4141
229
229
229
229
229
6
5
229
7
229
229
www.jeld-wen.co.uk
9
229
10
229
11
229
12
229
229
229
229
229
188
229
229
13
229
1
229
229
229
Dimension 'H' :
2755
B:Face of bottom riser to back of top riser
H:Minimum distance to give statutory headroom
(Based on storey heights between 2588mm
up to 2680mm with 339mm floor zone)
Headroom based on storey heights between 2588mm
up to 2680mm with 339mm floor zone.
Unobstructed width dimension does not allow for a wall handrail;
should this be a requirement the projection of the handrail would
need to be deducted.
2
8
229
Loose
Dimension ‘H’: 2755
Dimensions
229
229
229
229
229
188
41
2
(Width overall strings)
905
1
229
Width overall strings: 905
229
Unobstructed width: 860
Minimum trim width: 1015
Unobstructed width: 860
Min. trim width: 1015
229
Layout B
Dimension ‘A’: 3420
1
Loose
699
4141
41
1
20
12
13
Loose
229
229
229
229
229
229
229
229
229
229
229
229
229
229
229
229
188
11
10
9
8
7
6
5
229
229
188
41
2
Width overall strings: 905
229
229
229
Unobstructed width: 860
Dimension ‘H’: 1015
Dimension ‘B’: 892
4
3
2
229
229
229
229
229
229
229
229
229
229
19
Note: Landing
boards and
bearers are not
included
Minimum trim length: 3454
Dimensions
A: Wall string to back of top riser
B:Face of bottom riser to back of wall string
H:Minimum distance to give statutory headroom (Based on storey heights
between 2588mm up to 2680mm with 339mm floor zone)
Headroom based on storey heights between 2588mm up to 2680mm
with 339mm floor zone.
Unobstructed width dimension does not allow for a wall handrail; should this
be a requirement the projection of the handrail would need to be deducted.
Layout C
Trim Length: 2767
Dimension ‘A’: 2733
4
6
5
229
229
683
Loose
4141
40
42
2
19
229
3
229
229
2
229
188
229
7
229
8
229
9
229
10
229
11
229
12
13
Loose
229
229
229
229
229
229
229
229
229
229
229
188
41
3
Width overall strings: 905
Dimension ‘H’: 1590
Dimension ‘B’: 1579
Note: Landing
boards and
bearers are not
included
229
229
Unobstructed width: 860
229
19
187
188
1
41
42
229
1
229
187
Loose
Dimensions
Width overall strings: 905
A: Wall string to back of top riser
B: Face of bottom riser to back of wall string
H:Minimum distance to give statutory headroom (Based on storey heights between
2588mm up to 2680mm with 339mm floor zone)
Headroom based on storey heights between 2588mm up to 2680mm with 339mm floor zone.
Unobstructed width dimension does not allow for a wall handrail; should this be a requirement
the projection of the handrail would need to be deducted.
For further information and prices call 0845 122 2890
3
STAIR LAYOUTS
Layout D
Trim width: 2061
Dimension ‘A’: 2013
19
20
229
Note: Landing
boards and
bearers are not
included
6
229
7
4141
41
41
4141
41
41
2
20
229
4
229
Unobstructed width: 860
229
3
229
229
2
229
3
19
229
8
229
188
188
229
229
229
9
229
229
229
10
229
229
229
11
229
188
229
12
229
188
Trim length: 2080
Loose
Dimension ‘C’: 2047
A: Wall string to wall string
B: Face of bottom riser to back of wall string
C: Back of top riser to wall string
H:Minimum distance to give statutory headroom
(Based on storey heights between 2588mm
up to 2680mm with 339mm floor zone)
Headroom based on storey heights between 2588mm
up to 2680mm with 339mm floor zone.
Unobstructed width dimension does not allow for
a wall handrail; should this be a requirement the
projection of the handrail would need to be deducted.
Dimension ‘B’: 1809
Dimensions
Dimension ‘H’: 1820
Loose
684
683
5
1
41
42
229
229
1
187
Loose
Width overall strings: 905
4
41
13
Loose
Width overall strings: 905
Layout E
Trim width: 1931
Dimension ‘A’: 1881
Note: Landing
boards and bearers
are not included
6
14
229
7
229
229
5
229
188
188
229
4
229
229
229
229
8
229
229
229
229
9
229
229
229
10
229
229
229
11
229
188
229
12
229
Unobstructed width: 860
229
3
229
229
2
229
188
1
41
42
229
1
229
187
Loose
Width overall strings: 905
3
41
13
Loose
Width overall strings: 905
www.jeld-wen.co.uk
4
Trim length: 2311
2
41
41
41 146641
19
Dimension ‘C’: 2276
A: Wall string to wall string
B: Face of bottom riser to back of wall string
C: Back of top riser to wall string
H:Minimum distance to give statutory headroom
(Based on storey heights between 2588mm
up to 2680mm with 339mm floor zone)
Headroom based on storey heights between
2588mm up to 2680mm with 339mm floor zone.
Unobstructed width dimension does not allow for
a wall handrail; should this be a requirement the
projection of the handrail would need to be deducted.
Dimension ‘H’: 2050
Dimensions
Dimension ‘B’: 2038
Loose
Layout F
Minimum trim width: 1965
Dimension ‘A’: 1917
Note: Landing
boards and bearers
are not included
6
A: Wall string to wall string
B: Face of bottom riser to back of wall string
C: Back of top riser to wall string
H:Minimum distance to give statutory headroom
(Based on storey heights between 2588mm
up to 2680mm with 339mm floor zone)
Headroom based on storey heights between
2588mm up to 2680mm with 339mm floor zone.
Unobstructed width dimension does not allow for a
wall handrail; should this be a requirement the projection
of the handrail would need to be deducted.
3
1502 41
41
14
229
7
229
229
5
229
188
188
229
4
229
229
229
229
8
229
229
229
229
9
229
229
229
10
229
229
229
11
229
188
229
12
229
Unobstructed width: 860
229
3
229
229
2
229
188
Trim length: 2311
Dimensions
2
41
41
19
Dimension ‘C’: 2276
Dimension ‘B’: 2038
Dimension ‘H’: 2050
Loose
1
41
42
229
1
229
187
Loose
Width overall strings: 905
4
41
13
Loose
Width overall strings: 905
Layout G
Trim length: 2624
Dimension ‘A’: 2589
6
Dimension ‘H’: 1440
Dimension ‘B’: 1435
5
229
285
Loose
285
549
229
3
285
2
229
4834
49 45
33
44
7
229
8
229
9
229
10
229
11
229
12
229
229
229
229
229
229
2
229
13
Loose
229
229
229
229
229
188
41
Width overall strings: 905
401
4
229
229
547
Unobstructed width: 860
403
3
188
1
41
42
229
1
229
187
Loose
Dimensions
Width overall strings: 905
A: Wall string to back of top riser
B: Face of bottom riser to back of wall string
H:Minimum distance to give statutory headroom (Based on storey heights
between 2588mm up to 2680mm with 339mm floor zone)
Headroom based on storey heights between 2588mm up to 2680mm with 339mm floor zone.
Unobstructed width dimension does not allow for a wall handrail; should this be a requirement
the projection of the handrail would need to be deducted.
For further information and prices call 0845 122 2890
5
STAIR LAYOUTS
Layout H
Dimension ‘B’: 2809
1
2
3
4
229
229
229
Loose
229
187 4241
549
229
229
229
229
229
229
401
403
5
6
7
8
9
229
229
229
229
285
10
Loose
285
547
11
1
285
3349
44 48
34
45
2
188
229
229
229
229
229
229
188
229
12
Dimension ‘A’: 1215
229
Unobstructed width: 860
Width overall strings: 905
Trim width: 1205
229
229
3
41
13
Dimension ‘H’: 2815
Loose
Width overall strings: 905
Dimensions
A: Wall string to back of top riser
B: Face of bottom riser to back of wall string
H:Minimum distance to give statutory headroom (Based on storey heights between
2588mm up to 2680mm with 339mm floor zone)
Headroom based on storey heights between 2588mm up to 2680mm with 339mm floor zone.
Unobstructed width dimension does not allow for a wall handrail; should this be a requirement the
projection of the handrail would need to be deducted.
Layout I
Trim length: 2920
Dimension ‘A’: 2870
Dimension ‘H’: 1250
Dimension ‘B’: 1206
229
285
Loose
285
549
229
2
285
1
229
4834
49 45
33
44
2
1
401
403
6
7
8
9
229
229
229
285
10
Loose
285
11
3349
44 48
34
45
229
229
229
229
12
4
41
13
Loose
Dimensions
Width overall strings: 905
A: Wall string to wall string
B: Face of bottom riser to back of wall string
C: Back of top riser to wall string
H:Minimum distance to give statutory headroom
(Based on storey heights between 2588mm
up to 2680mm with 339mm floor zone)
Headroom based on storey heights between
2588mm up to 2680mm with 339mm floor zone.
Unobstructed width dimension does not allow for a wall
handrail; should this be a requirement the projection of
the handrail would need to be deducted.
6
www.jeld-wen.co.uk
547
285
3
188
188
41
229
549
229
Width overall strings: 905
229
Trim width: 1250
5
4
229
Dimension ‘C’: 1215
401
3
229
229
547
Unobstructed width: 860
403
Layout J
Trim width: 2004
Dimension ‘A’: 1954
534
416
546
404
384
394
7
Dimension ‘H’: 1708
Dimension ‘B’: 1664
Dimensions
8
285
Loose
285
285
Loose
556
566
9
229
3
285
3844
3547
54 4545 61
28
21
44
45
285
4
2
3
229
229
229
229
10
229
229
229
11
229
188
229
12
229
Trim length: 1708
285
5
Dimension ‘C’: 1673
905
6
Unobstructed width: 860
A: Wall string to wall string
B: Face of bottom riser to back of wall string
C: Back of top riser to wall string
H:Minimum distance to give statutory headroom
(Based on storey heights between 2588mm
up to 2680mm with 339mm floor zone)
Headroom based on storey heights between 2588mm
up to 2680mm with 339mm floor zone.
Unobstructed width dimension does not allow for a
wall handrail; should this be a requirement the projection
of the handrail would need to be deducted.
229
2
188
229
1
41
42
229
229
1
187
4
41
Loose
13
Loose
Width overall strings: 905
Layout K
Width overall strings: 905
Trim width: 1929
Dimension ‘A’: 1879
537
376
531
381
419
424
7
6
Loose
Loose
272
Dimensions
8
272
272
Loose
526
4
229
3
272
2
229
A: Wall string to wall string
B: Face of bottom riser to back of wall string
229
1
229
C: Back of top riser to wall string
H:Minimum distance to give statutory headroom
(Based on storey heights between 2588mm
Width overall strings: 905
up to 2680mm with 339mm floor zone)
Headroom based on storey heights between
2588mm up to 2680mm with 339mm floor zone.
Unobstructed width dimension does not allow for a wall handrail;
should this be a requirement the projection of the handrail would
need to be deducted.
Loose
1871 7514
57
61
25
21
45
44
229
229
Unobstructed width: 810
229
531
9
2
188
272
229
229
10
229
229
229
11
229
188
229
12
229
Trim length: 1708
Loose
5
Dimension ‘C’: 1673
Dimension ‘H’: 1708
Dimension ‘B’: 1664
272
1
41
42
187
3
41
13
Loose
Width overall strings: 905
For further information and prices call 0845 122 2890
7
STAIR LAYOUTS
Layout L
Trim width: 1833
Dimension ‘A’: 1783
338
535
495
361
422
433
7
6
Loose
Loose
Loose
259
259
Loose
506
4
229
229
517
9
3
2
229
Unobstructed width: 810
2
259
7 50396
57 1
50
25 17
3333
259
229
229
229
229
10
229
188
229
229
11
229
229
12
229
Trim length: 1697
5
Dimension ‘C’: 1662
A: Wall string to wall string
B: Face of bottom riser to back of wall string
C: Back of top riser to wall string
H:Minimum distance to give statutory headroom
(Based on storey heights between 2588mm
up to 2680mm with 339mm floor zone)
Headroom based on storey heights between
2588mm up to 2680mm with 339mm floor zone.
Unobstructed width dimension based on a ‘pigs ear’
wall handrail with a 50mm projection being incorporated;
should a different type be used the difference in projection
would need to be taken into account.
Dimension ‘H’: 1697
Dimension ‘B’: 1653
Dimensions
8
259
259
1
41
42
229
1
188
187
229
3
41
Loose
13
Loose
Width overall strings: 905
Layout M
Width overall strings: 905
Trim length: 2665
Dimension ‘A’: 2630
Loose
234
3
Loose
234
1
229
Loose
Width overall strings: 905
A: Wall string to back of top riser
B:Face of bottom riser to wall string
H:Minimum distance to give statutory headroom (Based on storey
heights between 2588mm up to 2680mm with 339mm floor zone)
Headroom based on storey heights between 2588mm up to 2680mm
with 339mm floor zone.
Unobstructed width dimension does not allow for a wall handrail;
should this be a requirement the projection of the handrail would
need to be deducted.
8
www.jeld-wen.co.uk
2 6220
86
60
20
85
229
229
229
229
7
8
9
10
11
12
229
229
229
229
229
229
229
229
13
Loose
1
2
Loose
Dimensions
229
234
234
381
229
6
5
4
229
229
229
229
229
229
188
41
2
Width overall strings: 905
Dimension ‘H’: 1255
Dimension ‘B’: 1247
610
229
229
381
Unobstructed width: 860
607
3
Layout N
Trim length: 2894
Dimension ‘A’: 2859
Loose
234
2
Loose
234
5
6
229
229
234
381
2 6220
86
60
20
85
7
8
9
10
11
12
229
229
229
229
229
229
Loose
1
1
234
Loose
188
229
229
229
229
229
229
229
13
41
2
Width overall strings: 905
4
3
Unobstructed width: 860
Dimension ‘B’: 1018
Dimension ‘H’: 1040
610
229
229
229
229
229
229
229
229
381
607
3
Width overall strings: 905
Dimensions
A: Wall string to back of top riser
B:Face of bottom riser to back of wall string
H:Minimum distance to give statutory headroom (Based on storey heights between
2588mm up to 2680mm with 339mm floor zone)
Headroom based on storey heights between 2588mm up to 2680mm with 339mm floor zone.
Unobstructed width dimension does not allow for a wall handrail; should this be a requirement
the projection of the handrail would need to be deducted.
Layout O
Trim length: 1978
Dimension ‘A’: 1943
234
6
Dimensions
A: Wall string to back of top riser
B: Face of bottom riser to back of wall string
H:Minimum distance to give statutory headroom
(Based on storey heights between 2588mm
up to 2680mm with 339mm floor zone)
Headroom based on storey heights between
2588mm up to 2680mm with 339mm floor zone.
Unobstructed width dimension does not allow for a wall
handrail; should this be a requirement the projection of
the handrail would need to be deducted.
Dimension ‘H’: 1945
Dimension ‘B’: 1934
Loose
9
8
7
Loose
229
234
234
381
2 6220
86
60
20
85
229
229
10
11
12
229
229
229
Loose
2
5
234
229
4
229
229
229
3
229
229
229
2
229
229
13
229
229
188
41
3
Width overall strings: 905
610
229
229
381
Unobstructed width: 860
607
3
188
1
41
42
229
1
229
187
Loose
Width overall strings: 905
For further information and prices call 0845 122 2890
9
STAIR LAYOUTS
Layout P
Trim width: 2086
Dimension ‘A’: 2036
607
Dimension ‘H’: 1520
Dimension ‘B’: 1476
Dimensions
A: Wall string to wall string
B: Face of bottom riser to back of wall string
C: Back of top riser to wall string
H:Minimum distance to give statutory headroom
(Based on storey heights between 2588mm
up to 2680mm with 339mm floor zone)
Headroom based on storey heights between
2588mm up to 2680mm with 339mm floor zone.
Unobstructed width dimension does not allow for a
wall handrail; should this be a requirement the projection
of the handrail would need to be deducted.
4
7
6
5
Loose
607
Loose
234
234
234
234
9
234
381
20602
2 6220
86 85
62
60
20
20
86
85
2
3
234
2
3
8
234
Loose
229
610
3
188
229
234
Loose
381
10
Unobstructed width: 860
229
229
11
229
188
229
12
229
Trim length: 1520
610
381
381
Dimension ‘C’: 1485
3
1
41
42
229
1
229
187
4
41
Loose
13
Loose
Width overall strings: 905
Layout Q
Width overall strings: 905
Trim length: 1915
Dimension ‘A’: 1865
551
Dimension ‘H’: 905
Dimension ‘B’: 892
100
Note: Landing
boards and
bearers are not
included
399
398
2
Loose
3
285
Loose
285
1
793
4
Loose
200
52 76 51
41
50
32
45
552
285
Dimensions
A: Wall string to wall string
B: Face of bottom riser to back of wall string
C: Back of top riser to wall string
H:Minimum distance to give statutory headroom (Based on storey heights
between 2588mm up to 2680mm with 339mm floor zone)
Headroom based on storey heights between 2588mm up to 2680mm
with 339mm floor zone.
Unobstructed width dimension does not allow for a wall handrail; should this
be a requirement the projection of the handrail would need to be deducted.
229
229
5
229
229
229
6
229
229
229
7
229
Unobstructed width: 860
229
229
8
229
229
229
9
229
229
229
10
229
229
229
11
229
188
229
12
229
2
41
13
Loose
10
www.jeld-wen.co.uk
Width overall strings: 905
Trim width: 2853
Width overall strings: 905
Dimension ‘C’: 2818
1
Layout R
Trim width: 2233
Dimension ‘A’: 2183
403
549
229
547
401
403
4
905
285
3
6
229
285
7
Loose
285
285
549
547
8
2
285
4834
49 44
33
44
229
1
229
229
3349
44 48
34
45
1
Loose
285
2
229
229
229
9
229
229
10
229
Loose
Dimensions
229
A: Wall string to wall string
Width overall strings: 905
B: Face of bottom riser to back of wall string
C: Back of top riser to wall string
H:Minimum distance to give statutory headroom (Based on storey heights
between 2588mm up to 2680mm with 339mm floor zone)
Headroom based on storey heights between
2588mm up to 2680mm with 339mm floor zone.
Unobstructed width dimension does not allow for a wall handrail; should this
be a requirement the projection of the handrail would need to be deducted.
Layout S
Trim length: 1937
Loose
5
Dimension ‘C’: 1902
Dimension ‘H’: 1225
Dimension ‘B’: 1206
401
Unobstructed width: 860
229
229
11
229
188
229
12
229
3
41
13
Loose
Width overall strings: 905
Trim length: 2842
Dimension ‘A’: 2733
2
229
Note: Landing boards
and bearers are not
included
229
6
5
229
7
229
8
229
9
229
10
229
11
229
12
13
Loose
Dimension ‘H’: 1590
Dimension ‘B’: 1578
229
229
229
229
229
229
229
229
4
Loose
684
4141
41
41
6
4
41
41
187
3
229
188
229
229
229
229
229
229
188
41
5
Width overall strings: 905
837
187
Unobstructed width: 815
188
2
229
188
1
3
41
41
188
41
42
1
229
187
Loose
Width overall strings: 905
Dimensions
A: Pulpit end string to back of top riser
B:Face of bottom riser to wall string
H:Minimum distance to give statutory headroom (Based on storey heights
between 2588mm up to 2680mm with 339mm floor zone)
Headroom based on storey heights between 2588mm up to 2680mm with 339mm floor zone.
For further information and prices call 0845 122 2890
11
STAIR LAYOUTS
Layout T
Dimension ‘B’: 2952
Width overall strings: 905
6
16
41
Loose
188
15
229
229
14
-229
229
Dimension ‘H’: 2960
188
5
1
229
229
2
3
4
5
229
229
229
229
Loose
229
188 4141
2
188
229
229
229
229
229
229
229
229
6
7
8
9
229
229
229
229
41
20
Note: Landing
boards and
bearers are not
included
Dimension ‘A’: 1812
188
187 4241
Unobstructed width: 815
Width overall strings: 905
Trim width: 1832
1
10
Loose
684
4141
41
41
3
229
229
229
188
188
188
19
229
11
229
229
12
229
4
41
Dimensions
A: Back of top riser to back of top riser
B:Face of bottom riser to back of wall string
H:Minimum distance to give statutory headroom (Based on storey
heights between 2588mm up to 2680mm with 339mm floor zone)
Headroom based on storey heights between 2588mm up to 2680mm
with 339mm floor zone.
12
www.jeld-wen.co.uk
13
Width overall strings: 905