Alarm Codes AIn HIdc I-Ac I-En LIL S-Ac S-En Analog Input Signal Loss High DC Bus Warning V/Hz Identification Active V/Hz Identification Enabled Low Input Line Vector Self-Tuning Active Vector Self-Tuning Enabled AIn bYC CHS EC EEr EL FL HId HIL HU IPL LU nCL nId OC OCA OCb OCd OF OH OL OPL OSP PUc PUn PUo SF Srl UAr UbS Analog Input Signal Loss DC Bus Charging Bypass Not Closed Checksum Error Earth Current Failure (Ground Fault) Non-volatile Memory Failure Encoder Loss Function Loss V/Hz Identification Aborted High Input Line High DC Bus Fault Input Phase Loss Low DC Bus Fault Network Comm Loss V/Hz Identification Not Performed Overcurrent Overcurrent at Acceleration Overcurrent at DC Braking Overcurrent at Deceleration Overfrequency Drive Overtemperature Motor Overload Motor Output Phase Loss Overspeed (Vector Only) Missing Power Module ID Connector Power Module Not Identified Power Module Overload Vector Self-Tuning Aborted Serial Comm Lost PC Comm Spurious Interrupt Asymmetrical Bus Charge Fault Codes ATTENTION: This material is not intended to provide operational instructions. Qualified electrical personnel must read and understand the applicable instruction manuals in their entirety prior to installing, adjusting, operating, and servicing this equipment. Failure to observe this precaution could result in severe bodily injury or loss of life. Printed in U.S.A. D-157-2 March 2001 Regulator Board Terminal Strip 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. RS-232 Transmit* RS-232 Receive* RS-232 Common* Encoder +15 Volts Encoder Phase A Encoder Phase A Not Encoder Phase B Encoder Phase B Not Encoder Common Analog Meter Output Analog Meter Common Isolated Reference Voltage Vdc Analog Speed Reference mA Analog Speed Reference Isolated Reference Ground Digital Input +24 Volts Digital Input 8 (Rem/Loc) Digital Input 7 (Ramp1/Ramp2) Digital Input 6 (Fwd/Rev) Function Loss Run/Jog Reset Stop Start +24 Vdc Common Snubber Resistor Braking Output* +24 Vdc Common* N.C. Relay Contact** N.C. Relay Common** N.O. Relay Contact** N.O. Relay Common** RMI Terminal Strip 41. 42. 43. 44. 45. 46. 47. 48. 49. 50. 51. 52. 53. 54. 55. 56. 57. 58. 59. 60. 61. 62. 63. 64. 65. 66. 67. 68. 69. Digital Input 1 Digital Input 2 Digital Input 3 Digital Input 4 Digital Input +24 Vdc Digital Output External +24 Vdc Digital Output 1 Digital Output 2 Digital Output 3 Digital Output 4 Digital Output Common Relay 1 Common Relay 1 N.O. Relay 2 N.C. Relay 2 Common Relay 2 N.O. Not Used Relay 3 N.C. Relay 3 Common Relay 3 N.O. Not Used Analog Input 0 – 10 Vdc Analog Input 0 – 20 mA Analog Input Common Analog Output 1: 0 to 10 Vdc Analog Output 2: +/- 10 Vdc Analog Output 3: 0 to 10 Vdc; 0 to 20 mA Analog Output Common Frequency Input: 0 to 200 kHz GV3000/SE AC Drive Quick Reference Version 6.06 *Not available on Bookshelf drives. **Located on remote terminal strip on Bookshelf drives. Refer to the following software (S/W) and hardware (H/W) manuals for detailed information about the GV3000/SE AC drive. GV3000/SE Drive 1 to 400 HP @ 460 VAC 75 to 200 HP @ 460 VAC 1 to 20 HP @ 230 VAC 30 to 100 HP @ 230 VAC 2 to 30 A Bookshelf S/W I/M D2-3359 D2-3391 D2-3387 D2-3416 D2-3426 H/W I/M D2-3360 D2-3392 D2-3388 D2-3417 D2-3427 Refer to the following manual for detailed information about the Super Remote Meter Interface (RMI) board: • D2-3341 Super Remote Meter Interface (RMI) Board for use with GV3000/SE and VTAC 7 Drives D-157-2 General Parameters P.000 P.001 P.002 P.003 P.004 P.005 P.006 Control Source Accel Time 1 (Ramp 1) Decel Time 1 (Ramp 1) Minimum Speed Maximum Speed Current Limit Second Menu Password P.007 P.008 P.009 P.010 P.011 P.012 P.013 P.014 P.015 P.016 P.017 P.018 P.019 P.020 P.021 P.022 P.023 P.024 P.025 P.026 P.027 P.028 P.029 P.030 P.031 P.032 P.033 P.034 P.035 P.036 P.037 P.038 P.039 P.040 P.041 P.042 P.043 P.044 P.045 P.047 P.048 P.049 TS Digital Inputs Config TS Speed Ref Source TS Analog Input Offset TS Analog Input Gain TS Analog Input Config TS Analog Output Source Output Relay Config Trim Ref Source Trim Gain Percentage Draw Gain Percentage Accel Time 2 (Ramp 2) Decel Time 2 (Ramp 2) S-Curve Enable Jog Speed Ref Jog Ramp Accel Time Jog Ramp Decel Time MOP Acc/Dec Time MOP Reset Configuration Stop Type Function Loss Response Fwd/Rev Configuration Speed Display Scaling Elapsed Time Meter Elapsed Time Meter Reset Preset Speed 1 Preset Speed 2 Preset Speed 3 Preset Speed 4 Preset Speed 5 Preset Speed 6 Preset Speed 7 Preset Speed 8 Encoder Loss Enable Motor Overload Enable Motor Overload Type Line Dip Ride-Through Time Fault Auto Reset Attempts Fault Auto Reset Time Output Phase Loss Enable Carrier Frequency Volts/Hertz or Vector Regulation Country Defaults General Parameters (Continued) P.050 P.051 P.052 P.053 P.054 P.055 P.060 P.061 P.062 P.063 P.064 P.065 P.066 P.067 P.068 P.069 P.090 P.091 P.095 P.098 P.099 Restore Defaults Programming Disable AUTO/MAN Key Disable Manual Ref Preset Enable Level Sense Start Enable STOP/RESET Key Disable Network Drop Number Network Connection Type Comm Loss Response Network Ref Source Network Trim Ref Source Option Port: Type and Version Network Output Reg 1 Source Network Output Reg 2 Source Network Output Reg 3 Source Network Output Reg 4 Source Diagnostics Source Diagnostics Display Power Module Output Amps Software Version Number Power Module Type H.000 H.001 H.002 H.003 H.004 H.005 H.006 H.007 H.008 H.009 H.010 H.011 H.012 H.013 H.014 H.015 H.016 H.017 H.018 H.019 H.020 H.021 H.022 Motor Nameplate Volts Motor Nameplate Base Freq Motor Nameplate Amps Torque Boost Voltage Slip Compensation DC Braking Enable DC Braking Start Freq DC Braking Current DC Braking Time Avoidance Freq Enable Avoidance Freq Midpoint 1 Avoidance Freq Band 1 Avoidance Freq Midpoint 2 Avoidance Freq Band 2 Avoidance Freq Midpoint 3 Avoidance Freq Band 3 Sync Direction Input Power/Snubber Config V/Hz Curve Type Identification Result Identification Request AC Line Volts Overfrequency Limit ________ ________ ________ ________ Volts/Hertz Parameters Vector Parameters U.000 U.001 U.002 U.003 U.004 U.005 U.006 U.007 U.008 U.009 U.012 U.013 U.014 U.015 U.016 U.017 U.018 U.019 U.020 U.021 U.022 U.023 U.024 U.025 U.026 U.027 U.028 U.030 U.031 U.032 U.040 U.041 U.042 U.043 U.044 U.045 U.046 U.047 U.048 Torque Ref Source Encoder PPR Motor Poles Motor Nameplate Base Freq Motor Nameplate Amps Motor Nameplate RPM Magnetizing Current Motor Nameplate Volts Torque Self-Tune Enable Torque Self-Tune Result Speed Reg Prop Gain Speed Reg Integral Gain Torque Reg Prop Gain Torque Reg Integral Gain Field Weakening Start RPM Motor Top Speed AC Line Volts Flux Curr Reg Prop Gain Flux Curr Reg Int Gain Rotor Time Const Motor Nameplate Horsepower Low DC Bus Fault Avoidance High DC Bus Fault Avoidance Zero Speed Hold Time Current Compounding Gain Inertia Compensation Gain Losses Compensation Gain SVC Slip Adjust SVC Sync Direction SVC Flux Curr Reg Gain OCL Feedback Source OCL Lead/Lag Select OCL Lead/Lag Low Freq OCL Lead/Lag Ratio OCL Ref Gain OCL Proportional Gain OCL Integral Gain OCL Trim Range Percentage OCL Prop Trim Enable RMI Parameters ________ r.001 r.002 r.003 r.004 r.005 r.006 r.007 r.008 r.009 r.010 r.011 r.014 r.015 r.016 r.020 r.021 r.022 r.025 r.030 r.031 r.032 r.033 r.034 r.035 r.036 r.037 r.040 r.041 r.042 r.043 r.044 r.045 r.046 r.050 r.051 r.052 r.053 r.056 r.057 r.058 r.059 r.060 r.063 r.064 r.065 r.066 Analog Output 1 Source Analog Output 1 Offset Analog Output 1 Gain Analog Output 2 Source Analog Output 2 Offset Analog Output 2 Gain Analog Output 3 Source Analog Output 3 Offset Analog Output 3 Gain Analog Input Offset Analog Input Gain Freq Input Sample Period Frequency Input Offset Frequency Input Gain PI Regulator Offset PI Regulator Prop Gain PI Regulator Integral Gain Torque/Current Limit Source Digital Input Config Digital Output 1 Config Digital Output 2 Config Digital Output 3 Config Digital Output 4 Config Relay Output 1 Config Relay Output 2 Config Relay Output 3 Config Digital Output 1 Delay Time Digital Output 2 Delay Time Digital Output 3 Delay Time Digital Output 4 Delay Time Relay Output 1 Delay Time Relay Output 2 Delay Time Relay Output 3 Delay Time Speed Detection Level 1 Speed Detection Level 2 Speed Detection Level 3 Speed Detect Hysteresis Low Speed Detection Level Current Detection Level 1 Current Detection Level 2 Current Detection Level 3 ________ Current Detection Hysteresis Torque Detection Level 1 Torque Detection Level 2 Torque Detection Level 3 Torque Detection Hysteresis ________ General Parameters P.000 P.001 P.002 P.003 P.004 P.005 P.006 Control Source Accel Time 1 (Ramp 1) Decel Time 1 (Ramp 1) Minimum Speed Maximum Speed Current Limit Second Menu Password P.007 P.008 P.009 P.010 P.011 P.012 P.013 P.014 P.015 P.016 P.017 P.018 P.019 P.020 P.021 P.022 P.023 P.024 P.025 P.026 P.027 P.028 P.029 P.030 P.031 P.032 P.033 P.034 P.035 P.036 P.037 P.038 P.039 P.040 P.041 P.042 P.043 P.044 P.045 P.047 P.048 P.049 TS Digital Inputs Config TS Speed Ref Source TS Analog Input Offset TS Analog Input Gain TS Analog Input Config TS Analog Output Source Output Relay Config Trim Ref Source Trim Gain Percentage Draw Gain Percentage Accel Time 2 (Ramp 2) Decel Time 2 (Ramp 2) S-Curve Enable Jog Speed Ref Jog Ramp Accel Time Jog Ramp Decel Time MOP Acc/Dec Time MOP Reset Configuration Stop Type Function Loss Response Fwd/Rev Configuration Speed Display Scaling Elapsed Time Meter Elapsed Time Meter Reset Preset Speed 1 Preset Speed 2 Preset Speed 3 Preset Speed 4 Preset Speed 5 Preset Speed 6 Preset Speed 7 Preset Speed 8 Encoder Loss Enable Motor Overload Enable Motor Overload Type Line Dip Ride-Through Time Fault Auto Reset Attempts Fault Auto Reset Time Output Phase Loss Enable Carrier Frequency Volts/Hertz or Vector Regulation Country Defaults General Parameters (Continued) P.050 P.051 P.052 P.053 P.054 P.055 P.060 P.061 P.062 P.063 P.064 P.065 P.066 P.067 P.068 P.069 P.090 P.091 P.095 P.098 P.099 Restore Defaults Programming Disable AUTO/MAN Key Disable Manual Ref Preset Enable Level Sense Start Enable STOP/RESET Key Disable Network Drop Number Network Connection Type Comm Loss Response Network Ref Source Network Trim Ref Source Option Port: Type and Version Network Output Reg 1 Source Network Output Reg 2 Source Network Output Reg 3 Source Network Output Reg 4 Source Diagnostics Source Diagnostics Display Power Module Output Amps Software Version Number Power Module Type H.000 H.001 H.002 H.003 H.004 H.005 H.006 H.007 H.008 H.009 H.010 H.011 H.012 H.013 H.014 H.015 H.016 H.017 H.018 H.019 H.020 H.021 H.022 Motor Nameplate Volts Motor Nameplate Base Freq Motor Nameplate Amps Torque Boost Voltage Slip Compensation DC Braking Enable DC Braking Start Freq DC Braking Current DC Braking Time Avoidance Freq Enable Avoidance Freq Midpoint 1 Avoidance Freq Band 1 Avoidance Freq Midpoint 2 Avoidance Freq Band 2 Avoidance Freq Midpoint 3 Avoidance Freq Band 3 Sync Direction Input Power/Snubber Config V/Hz Curve Type Identification Result Identification Request AC Line Volts Overfrequency Limit ________ ________ ________ ________ Volts/Hertz Parameters Vector Parameters U.000 U.001 U.002 U.003 U.004 U.005 U.006 U.007 U.008 U.009 U.012 U.013 U.014 U.015 U.016 U.017 U.018 U.019 U.020 U.021 U.022 U.023 U.024 U.025 U.026 U.027 U.028 U.030 U.031 U.032 U.040 U.041 U.042 U.043 U.044 U.045 U.046 U.047 U.048 Torque Ref Source Encoder PPR Motor Poles Motor Nameplate Base Freq Motor Nameplate Amps Motor Nameplate RPM Magnetizing Current Motor Nameplate Volts Torque Self-Tune Enable Torque Self-Tune Result Speed Reg Prop Gain Speed Reg Integral Gain Torque Reg Prop Gain Torque Reg Integral Gain Field Weakening Start RPM Motor Top Speed AC Line Volts Flux Curr Reg Prop Gain Flux Curr Reg Int Gain Rotor Time Const Motor Nameplate Horsepower Low DC Bus Fault Avoidance High DC Bus Fault Avoidance Zero Speed Hold Time Current Compounding Gain Inertia Compensation Gain Losses Compensation Gain SVC Slip Adjust SVC Sync Direction SVC Flux Curr Reg Gain OCL Feedback Source OCL Lead/Lag Select OCL Lead/Lag Low Freq OCL Lead/Lag Ratio OCL Ref Gain OCL Proportional Gain OCL Integral Gain OCL Trim Range Percentage OCL Prop Trim Enable RMI Parameters ________ r.001 r.002 r.003 r.004 r.005 r.006 r.007 r.008 r.009 r.010 r.011 r.014 r.015 r.016 r.020 r.021 r.022 r.025 r.030 r.031 r.032 r.033 r.034 r.035 r.036 r.037 r.040 r.041 r.042 r.043 r.044 r.045 r.046 r.050 r.051 r.052 r.053 r.056 r.057 r.058 r.059 r.060 r.063 r.064 r.065 r.066 Analog Output 1 Source Analog Output 1 Offset Analog Output 1 Gain Analog Output 2 Source Analog Output 2 Offset Analog Output 2 Gain Analog Output 3 Source Analog Output 3 Offset Analog Output 3 Gain Analog Input Offset Analog Input Gain Freq Input Sample Period Frequency Input Offset Frequency Input Gain PI Regulator Offset PI Regulator Prop Gain PI Regulator Integral Gain Torque/Current Limit Source Digital Input Config Digital Output 1 Config Digital Output 2 Config Digital Output 3 Config Digital Output 4 Config Relay Output 1 Config Relay Output 2 Config Relay Output 3 Config Digital Output 1 Delay Time Digital Output 2 Delay Time Digital Output 3 Delay Time Digital Output 4 Delay Time Relay Output 1 Delay Time Relay Output 2 Delay Time Relay Output 3 Delay Time Speed Detection Level 1 Speed Detection Level 2 Speed Detection Level 3 Speed Detect Hysteresis Low Speed Detection Level Current Detection Level 1 Current Detection Level 2 Current Detection Level 3 ________ Current Detection Hysteresis Torque Detection Level 1 Torque Detection Level 2 Torque Detection Level 3 Torque Detection Hysteresis ________ Alarm Codes AIn HIdc I-Ac I-En LIL S-Ac S-En Analog Input Signal Loss High DC Bus Warning V/Hz Identification Active V/Hz Identification Enabled Low Input Line Vector Self-Tuning Active Vector Self-Tuning Enabled AIn bYC CHS EC EEr EL FL HId HIL HU IPL LU nCL nId OC OCA OCb OCd OF OH OL OPL OSP PUc PUn PUo SF Srl UAr UbS Analog Input Signal Loss DC Bus Charging Bypass Not Closed Checksum Error Earth Current Failure (Ground Fault) Non-volatile Memory Failure Encoder Loss Function Loss V/Hz Identification Aborted High Input Line High DC Bus Fault Input Phase Loss Low DC Bus Fault Network Comm Loss V/Hz Identification Not Performed Overcurrent Overcurrent at Acceleration Overcurrent at DC Braking Overcurrent at Deceleration Overfrequency Drive Overtemperature Motor Overload Motor Output Phase Loss Overspeed (Vector Only) Missing Power Module ID Connector Power Module Not Identified Power Module Overload Vector Self-Tuning Aborted Serial Comm Lost PC Comm Spurious Interrupt Asymmetrical Bus Charge Fault Codes ATTENTION: This material is not intended to provide operational instructions. Qualified electrical personnel must read and understand the applicable instruction manuals in their entirety prior to installing, adjusting, operating, and servicing this equipment. Failure to observe this precaution could result in severe bodily injury or loss of life. Printed in U.S.A. D-157-2 March 2001 Regulator Board Terminal Strip 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. RS-232 Transmit* RS-232 Receive* RS-232 Common* Encoder +15 Volts Encoder Phase A Encoder Phase A Not Encoder Phase B Encoder Phase B Not Encoder Common Analog Meter Output Analog Meter Common Isolated Reference Voltage Vdc Analog Speed Reference mA Analog Speed Reference Isolated Reference Ground Digital Input +24 Volts Digital Input 8 (Rem/Loc) Digital Input 7 (Ramp1/Ramp2) Digital Input 6 (Fwd/Rev) Function Loss Run/Jog Reset Stop Start +24 Vdc Common Snubber Resistor Braking Output* +24 Vdc Common* N.C. Relay Contact** N.C. Relay Common** N.O. Relay Contact** N.O. Relay Common** RMI Terminal Strip 41. 42. 43. 44. 45. 46. 47. 48. 49. 50. 51. 52. 53. 54. 55. 56. 57. 58. 59. 60. 61. 62. 63. 64. 65. 66. 67. 68. 69. Digital Input 1 Digital Input 2 Digital Input 3 Digital Input 4 Digital Input +24 Vdc Digital Output External +24 Vdc Digital Output 1 Digital Output 2 Digital Output 3 Digital Output 4 Digital Output Common Relay 1 Common Relay 1 N.O. Relay 2 N.C. Relay 2 Common Relay 2 N.O. Not Used Relay 3 N.C. Relay 3 Common Relay 3 N.O. Not Used Analog Input 0 – 10 Vdc Analog Input 0 – 20 mA Analog Input Common Analog Output 1: 0 to 10 Vdc Analog Output 2: +/- 10 Vdc Analog Output 3: 0 to 10 Vdc; 0 to 20 mA Analog Output Common Frequency Input: 0 to 200 kHz GV3000/SE AC Drive Quick Reference Version 6.06 *Not available on Bookshelf drives. **Located on remote terminal strip on Bookshelf drives. Refer to the following software (S/W) and hardware (H/W) manuals for detailed information about the GV3000/SE AC drive. GV3000/SE Drive 1 to 400 HP @ 460 VAC 75 to 200 HP @ 460 VAC 1 to 20 HP @ 230 VAC 30 to 100 HP @ 230 VAC 2 to 30 A Bookshelf S/W I/M D2-3359 D2-3391 D2-3387 D2-3416 D2-3426 H/W I/M D2-3360 D2-3392 D2-3388 D2-3417 D2-3427 Refer to the following manual for detailed information about the Super Remote Meter Interface (RMI) board: • D2-3341 Super Remote Meter Interface (RMI) Board for use with GV3000/SE and VTAC 7 Drives D-157-2 U.S. Drives Technical Support Tel: (1) 262.512.8176, Fax: (1) 262.512.2222, Email: [email protected], Online: www.ab.com/support/abdrives Trademarks not belonging to Rockwell Automation are property of their respective companies. Publication D-157-2 – November 2006 Copyright © 2006 Rockwell Automation, Inc. All Rights Reserved. Printed in USA.
© Copyright 2026 Paperzz