TY3-4 - Hussmann

SELF-SERVICE DELI
REVISION DATE
02/06/17
HUSSMANN - TY3-4 I-ISLAND, E-END, REMOTE (CHINO)
REFRIGERATION DATA:
CAPACITY ***
(BTU/HR)
CASE LENGTHS
CASE USAGE
DELI
DELI
DELI
DELI
DELI
DELI
DELI
6I
8I
10I
12I
4E
6E
8E
RATING
CONDITION
AHRI
NSF 7
1200
9150
7800
12200
10400
15250
13000
18300
15600
6100
5200
9200
7800
12300
10400
TEMPERATURE (ºF)
EVAPORATOR
DISCHARGE
AIR ** (°F)
AHRI
1200
28
28
28
28
28
28
28
NSF 7
26
26
26
26
26
26
26
VELOCITY
(FT/MIN)
NSF 7
NSF 7
31~33
31~33
31~33
31~33
31~33
31~33
31~33
100~175
100~175
100~175
100~175
100~175
100~175
100~175
CASE
LENGTHS
6I
8I
10I
12I
4E
6E
8E
EST.
REFG.
CHRG.
(LBS)
1.1
1.1
1.3
1.8
0.8
1.1
1.3
20°F GLYCOL
6° RISE
GPM
PSI
2.8
3.7
4.5
5.4
3.5
4.3
5.1
3.6
5.0
3.5
4.7
4.2
6.2
4.2
**FRONT DISCHARGE AIR MEASURED INSIDE AIR CURTAIN HONEYCOMB
***REFRIGERATION NOTES:
1) BTUS DO NOT INCLUDE LIGHTS.
2) ADD 10 BTU'S PER FOOT OF LED SHELF LIGHTS PER LIGHT MATRIX BELOW.
3) AHRI 1200 RATING POINT FOR ENERGY CONSUMPTION COMPARISON ONLY.
4) USE DEW POINT FOR HIGH GLIDE REFRIGERANTS. CARE SHOULD BE TAKEN TO USE THE DEW POINT IN P/T TABLES
FOR MEASURING AND ADJUSTING SUPERHEAT. ADJUST EVAPORATOR PRESSURE AS NEEDED TO MAINTAIN THE
DISCHARGE AIR TEMPERATURE SHOWN.
5) RATING CONDITION IS NSF TYPE I, 75°F/55% RH.
REFRIGERATION DATA CONTINUED:
ELEC. THERMOSTAT / AIR
SENSOR SETTINGS
DEFROST
CUT
CUT IN
TYPE
OUT
USAGE
(ºF)
DELI
33
TIME
(MIN)
DEFROST
FREQUENCY
(#/DAY)
TERM.
TEMP
(°F)
COIL
ONLY
DRIP
TIME
DEFROST
WATER
(LBS/DAY/FT)
# OF END
PNLS
END PNL
WIDTH
(IN.)
TOTAL ADDED
LENGTH (IN.)
16
12
48
N/A
15
1
1.125
1.125
(ºF)
30
OFF TIME
END PANEL WIDTH KEY
ELECTRICAL DATA:
STANDARD FANS, HEATERS, LED LIGHTS (115 VOLT)
CANOPY LIGHTS OPTIONAL LED MAX. LED LOAD
LED
SHELF LIGHTS (W/ ALL OPTIONS)
EVAPORATOR FANS
CASE LENGTH
6I
8I
10I
12I
4E
6E
8E
# OF
EVAP
FANS
BLADE
DIA.
(IN.)
BLADE
PITCH (°)
AMPS
WATTS
AMPS
6
6
8
10
4
6
8
8
8
8
8
8
8
8
15
15
15
10
15
15
15
1.8
1.8
2.4
3.0
1.2
1.8
2.4
48
48
64
80
32
48
64
0.12
0.22
0.30
0.40
0.10
0.20
0.28
WATTS AMPS WATTS AMPS WATTS
14
25
35
46
12
23
33
OPTIONAL HIGH OUTPUT LED LIGHTS (115 VOLT)
CANOPY
MAX. H.O. LED
OPTIONAL SHELF
LIGHTS
LOAD
CASE LENGTH
H.O. LED
AMPS WATTS AMPS
WATTS AMPS WATTS
6I
N/A
N/A
N/A
N/A
N/A
N/A
8I
N/A
N/A
N/A
N/A
N/A
N/A
10I
N/A
N/A
N/A
N/A
N/A
N/A
12I
N/A
N/A
N/A
N/A
N/A
N/A
4E
N/A
N/A
N/A
N/A
N/A
N/A
6E
N/A
N/A
N/A
N/A
N/A
N/A
8E
N/A
N/A
N/A
N/A
N/A
N/A
0.25
0.44
0.61
0.79
0.21
0.40
0.57
29
50
70
91
24
46
65
0.37
0.65
0.91
1.19
0.31
0.60
0.85
ANTI-SWEAT
HEATERS (ON
FAN CIRCUIT)
AMPS
43
75
105
137
36
68
98
0.61
0.78
0.78
0.96
0.26
0.61
0.78
CONVENIENCE
OUTLETS (OPTIONAL)
#
WATTS OUTLETS VOLTS AMPS
70
90
90
110
30
70
90
1
1
1
1
1
1
1
115
115
115
115
115
115
115
15
15
15
15
15
15
15
CASE ENERGY USAGE DATA:
CASE LENGTH /
WEDGES
TDA/V (ft2/ft)
3
(ft wedges)
ACTUAL CDEC
(KWh/day/ft)
(KWh/day wedges)
MAX ALLOWABLE
CDEC (KWh/Day/ft)
(KWh/day wedges)
3',4',5',6',8',10',12'
22.5° IS
22.5° OS
45° OS
45° IS
90° OS
0
0
0
0
0.00
0
0.00
0.00
0.00
0.00
0.00
0.00
4.48
0.00
0.00
0.00
0.00
0.00
LIGHT
MATRIX
FT OF
LEDS
18'
30'
42'
54'
15'
27'
39'