www.habia.com

RG and SM
00
01
Coax
Flame retardant
02
Construction
IEC 60332-1-2
IEC 61034-2
Toxicity
IEC 60754-2
!()**+,+-#*./(,*+(0
Velocity propagation
Conductor
UL 1581 VW-1
Smoke generation
Frequency range
-65oC/+200oC
standard and sub-miniature coaxial cables
Shield
Silver Plated Copper (SPC)
Silver Plated High Strength Copper Alloy (HSA)
Braid of Silver Plated Copper (S)
Dielectric
PTFE
Sheath
FEP
!"#$%&'($%)#
Up to 2,5 GHz
Dielectric
Sheath
-40dB (single braid)
"8)9,+-
-70dB (double braid)
Natural
Brown-transparent
TYPE Habia Cable ORDER REFERENCE YEAR-WEEK BATCHCODE
(e.g. RG 142 Habia Cable 30000-142-50 2012-W20 121026001)
70%
03
Description
04
05
RG 142
06
RG 179
07
RG 178
RG 316
RG 400
!"#$%
08
09
!"#&$
!"#'$
conductor conductor
material
Ø
SPC
0,94
solid
SPC
0,30
7x 0,10
SPC
0,30
7x 0,10
SPC
0,54
7x 0,18
SPC
0,98
(9x 0,20
HSA
0,16
solid
HSA
0,10
solid
HSA
0,10
solid
Construction
dielectric shield (s) sheath (s)
Ø
Ø
Ø
S: 3,50
2,95
4,80
S: 4,10
weight
g/m
80
0,87
S: 1,37
1,75
8
1,60
S: 2,15
2,50
15
1,52
S: 2,05
2,45
15
2,95
S: 3,50
S: 4,15
4,80
64
0,52
S: 0,85
1,00
3
0,55
S: 0,90
1,00
3
0,95
S: 1,30
1,40
5
V rms
V DC
1400
2800
500
1000
900
1800
900
1800
1400
2800
400
800
300
600
400
800
Electrical
imp.
cap.
pF/m
50
95
50
94
75
63
50
94
50
94
50
94
75
63
95
50
MBR
static
dynamic
25
50
10
20
15
30
15
30
25
50
5
10
5
10
7
14
Order reference
30000-142-50
30000-178-50
30000-179-50
30000-316-50
30000-400-50
30000-050-00
30000-075-00
30000-095-00
10
11
12
13
14
15
16
17
18
A1
A2
Electrical data (table)
RG 142
RG 178
RG 179
RG 316
RG 400
!"#$%
!"#&$
!"#'$
Attenuation (dB/100m)
1)*23*+(0#4"567
30
7
25
15
15
8
36
36
26
100
13
46
28
27
15
65
65
47
400
26
93
56
54
31
130
130
95
1000
42
148
86
86
50
207
207
151
Power (W)
1)*23*+(0#4"567
2500
69
237
144
139
82
329
329
242
6000
-
30
2373
274
511
621
2008
117
117
219
100
1300
150
280
340
1100
64
64
120
Ref: RG_SM_03 Created: CJV Approved: AE Date: 2013-09-12
400
650
75
140
170
550
32
32
60
1000
411
47
89
108
348
20
20
38
2500
260
30
56
68
220
13
13
24
6000
-
Data indicates nominal values unless stated otherwise, is only valid for reference purposes at the time of publication and is subject to change without prior notice.
1108
www.habia.com
RG and SM
-65oC/+200oC
standard and sub-miniature coaxial cables
Application
Coaxials use solid PTFE dielectrics and FEP sheaths in order to offer high temperature properties. These coaxials typically use non-magnetic conductors which are less
susceptible to passive intermodulation as well as providing a more cost effective solution to the copper-covered steel conductor coaxes.
00
01
02
03
Electrical data (graph)
04
Attenuation (nom. at 20oC)
!!!
05
06
Attenuation (dB/100m)
!!
Black
Brown
Red
Grey
Brown Orange Green Blue -
!
07
RG 142
RG 178
RG 179
RG 316
RG 400
!"#$%
!"#&$
!"#'$
08
09
10
!
!!
!!!
!!!!
11
!!!!!
12
1)*23*+(0#4"567
o
Power rating (max. at 20 C, SWR 1.0 and sea level)
13
!!!!
14
15
!!!
Watts (W)
Black
Brown
Red
Grey
Brown Orange Green Blue -
!!
RG 142
RG 178
RG 179
RG 316
RG 400
!"#$%
!"#&$
!"#'$
16
17
18
A1
!
!
!!
!!!
!!!!
!!!!!
A2
1)*23*+(0#4"567
Ref: RG_SM_03 Created: CJV Approved: AE Date: 2013-09-12
Data indicates nominal values unless stated otherwise, is only valid for reference purposes at the time of publication and is subject to change without prior notice.
www.habia.com
1109